Major Parameters:
|
| 1)Power supply voltage:AC 660V/380V ±15% 50Hz Three phase AC |
| Capacity: Single-rail 3KVA ; Double-rail 6KVA |
| 2)Hoisting Type: hoist person and material (single-rail or double-rail) |
| 3)Brake Distance of the Winder:≤2m |
| 4)Max. Hoisting Distance of the Winder:1200m |
| 5)Max. Hoisting Speed of the Winder:9.9m/s |
| 6)Back-up Protection: |
| Distance detection: ≤300mm |
| Overwinding: 400mm—5000mm (to be determined by the customer) |
| Reserving deceleration point:later than the original deceleration pint of the winder 2m—5m |
| |
| Protection to wrong direction;Protection to depth indicator failure ; |
| 7)Absorber of the railing:to be supplied according to the customer |
| 8)Max. number of the railing:5 (recommend 3 railings) |
| 9)Permissible Power-cut duration:2 months |